Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 9/6/2018 2:01:07 PM
Test report 103536746MTL-002 (16 of 21)
TEST REPORT FOR STOVE BUILDER INTERNATIONAL INC.
Report No.: 103536746MTL-002
Date: 07/13/18
Where:
Et
= delivered heat output over any time interval t
i
= time interval for each measurement, h
The average heat output rate over any time interval shall be calculated as follows:
where
e
= average heat output, kJ/h
t
t
= time interval over which the average output is desired, h
The total heat output during the burn shall be calculated as the sum of all the heat outputs over
each time interval, as follows:
Where:
E
= heat output over a burn, kJ/h (Btu/h)
d
E
= heat output during each time interval, kJ/h (Btu/h)
t
The efficiency shall be calculated as the total heat output divided by the total energy input,
expressed as a percentage as follows:
Where:
E
= total heat output of the appliance over the test period, kJ/kg
d
I
= input energy (fuel calorific value as-fired times weight of fuel charge), kJ/kg (Btu/lb)
SECTION 9
TEST SPECIMEN DESCRIPTION
The model Solution 3.5 Series Wood Fuel Room Heater is constructed of sheet steel. The outer
dimensions are 33.75-inches deep, 34.438.-inches high, and 27.563-inches wide. The unit has a
door located on the front with a viewing glass.
SECTION 10
TEST RESULTS
DESCRIPTION OF TEST RUNS:
RUN #1 (May 22
with a category "low burn rate" of 1.5 kg/hr. Let the door ajar for 6.5 minutes, and then closed.
Version: 05/10/17
Stove Builder International Inc. | 44826 | Rev: Aug 31 2018 3:17PM | Uncontrolled Copy
E
= ∑(Δe × i) for i= t
to t
t
1
2
e
= E
/t
t
t
E
= ∑(E
) for t = t
to t
d
t
0
final
Efficiency, % = 100 × E
/I
d
nd
2018) Air control was set at the targeted burn rate, burn time was 510 minutes
–t
, kJ
2
1
Page 16 of 21
8431 Murphy Drive
Middleton, WI 53562
Telephone: 608-836-4400
Facsimile: 608-831-9279
www.intertek.com/building
GFT-OP-10c
Page 171 of 201