Installing the Outlet Air Pipe

It is important to ensure that the pipe has a diameter of 4
inside of the pipe must be smooth, preferably of a PP-type. Do not use any flexible ducts or pipes with a diameter of less than
4
in. (110 mm). The supplied ventilator cowl must be used. The length of the straight, vertical pipe MUST NOT exceed:
5
16
18 ft. (5.5 meters)
15 ft. (4.5 meters) if a pipe bend has been installed.
The pipe must extend at least 15
the best possible air flow. A horizontal pipe with a maximum length of 2 ft (600 mm) may be installed directly into the toilet, the
supplied pipe should be used. Try to install the outlet air pipe vertically, or as nearly vertical as possible.
IMPORTANT NOTE: Do not use any 90° bends in addition to the T-bend. Use no more than two 45° bends or two 30° bends
when installing the outlet air pipe; see example (fig 6).
Three examples of outlet air pipe installations.
fig. 4
IMPORTANT NOTE: Each Cinderella Comfort toilet must have its own outlet air pipe.
5
in. (400 mm) above the roof at the point where it is fed through the roof, in order to secure
3
4
fig. 5
in. (110 mm) all the way from the toilet to the ventilator cowl. The
16
2 ft
18 ft
16 ⁄ in.
(415 mm)
2 ft
15 ft
fig. 6
7