9.4
Timer setting for "Lock Out" relay contacts (1)
You can specify the activation time of the "Lock Out" relay contacts (1) (to which an electric door
opener may be connected) yourself. Enter the following key combination while in programming
mode to do so:
20 TT
In this case, TT stands for 01 to 99 seconds. If 00 is set, the relay contacts remain activated
until the user password is entered again. On this, see chapter: 9.10 Triggering of "Lock Out"
relay contacts (1).
9.5
Key lock
If the automatic key lock is activated, the code lock automatically locks all buttons for 30 sec-
onds after a user password or the Master Code has been entered incorrectly five times (factory
setting).
The automatic 30 second lock can be activated/deactivated. Enter the following key combination
while in programming mode to do so:
51
You can also specify after which errors the key lock should be activated. Enter the following key
combination while in programming mode to do so:
53 0
after the inputting of 20 incorrect digits in sequence
53 1
after five incorrect user password or Master Code inputs
9.6
Setting password for "Aux Out" relay contacts (6)
The factory setting is no password for "Aux Out" relay contacts (6).
Enter the following key combination in programming mode to assign a new password:
40 HHHH
HHHH in this case stands for the 4 digit combination of numbers you wish to assign as the
desired password.
9.6.1 Setting activation period for "Aux Out" relay contacts (6)
You can specify the activation time of the "Aux Out" relay contacts (i) (to which a door gong
may be connected) yourself. Enter the following key combination while in programming mode
to do so:
28