These alarm readings will remain on display until you press the 0/1 key on the control panel.
We recommend that you do NOT ignite the stove again before checking that you have solved the problem
In case of stove stoppage, to re-ignite the stove you must allow the stoppage procedure to take its course (this takes 10 minu-
tes and is followed by a sound alert), then press the 0/1 key.
Never pull the power plug out while the stove is shutting down because of a stoppage.
Important: report the readings that come up on the control panel to the Dealer.
TROUBLESHOOTING: WHAT TO DO IN CASE OF BREAKDOWNS
The pellets CANNOT drop into the combustion chamber for the following reasons:
The worm screw is empty:
Press the + and – keys at the same time to fill the worm screw .
The pellets are wedged in the reserve:
Use a vacuum cleaner to empty out the pellet reserve.
The gear is broken.
The worm screw safety thermostat has cut out the power supply to the gear:
Check that there is no overheating. Check this using a tester or by bridging temporarily.
The excessive water temperature safety thermostat has cut out the power supply to the gear:
Check whether the stove contains any water. To reset, press the key behind the stove.
In these cases, ALWAYS contact the Dealer BEFORE starting the stove up again.
PROBLEM
Control panel off
Inefficient remote control
Water is not hot enough
The chimneys and smoke flues connected to solid fuel-burning equipment must be cleaned (swept) once every year (check the
standards governing this requirement in your own country).
If you do not check and clean them regularly, you increase the probability of a chimney fire.
In case of a chimney fire, proceed as follows: do not use water to put the fire out; empty the pellets out of the reserve; contact
the Dealer before starting the stove up again after the fire.
03/07/2009
CAUSE
No power from the mains
You are too far from the stove
The remote control batteries are flat
Too much soot in the exchanger
39
12.25
Pagina 40
SOLUTIONS
Check the power supply connections
Check the fuse (on the power supply line)
Check the flat cable connection to the control
panel
Move closer to the stove
Check the batteries and change them if
necessary
Clean the exchanger from inside the
combustion chamber