Safety note indicating possible damage to
the unit/accessory.
Important
Serial number
The CE labelling certifies that the product
complies with the essential requirements of
Directive 93/42/EEC on medical products.
Disposal in accordance with EC Directive
(Waste Electrical and Electronic Equip-
ment).
Permissible storage temperature and
Storage
humidity

3. Notes

Please read these instructions for use carefully and keep them for later use, be sure to make them accessible to
other users and observe the information they contain.

Safety notes

Warning
• The light of the daylight therapy lamp is only intended for use on the human body.
• Before use, ensure that all packaging materials are removed and that there is no visible damage to the unit
or accessories. When in doubt, do not use the unit and contact your dealer or the customer service ad-
dress provided.
• Also ensure that the daylight therapy lamp has a firm footing.
• Connect the unit only to the mains voltage listed on the type plate.
• Do not dip the unit into water and do not use it in wet rooms.
• Do not use it in the vicinity of people who are helpless, children under age 3 or people who are insensitive to
heat (people with skin lesions due to illness); do not use after taking painkillers or drugs or drinking alcohol.
• Keep children away from packaging materials (risk of suffocation).
• Do not cover up or pack away the unit while it is warm.
• Always unplug the mains part and allow the device to cool down before touching it.
• Do not touch the unit with wet hands while it is plugged in; do not allow any water to be sprayed onto the
unit. The unit must be operated only when it is completely dry.
• Ensure that you only insert and remove the mains part with dry hands and that you only press the ON/OFF
button with dry hands.
• Keep the mains cable away from hot objects and naked flames.
• Danger of strangulation due to excessively long cables.
• Protect the unit from strong impacts.
• Do not pull the mains part out of the socket using the mains cable.
• If the mains part or its housing is damaged, this must be replaced by customer services or the retailer, as
a special tool is needed for repair.
• Disconnection from the power supply network is only guaranteed when the mains part is unplugged.
• Do not use the device in the presence of flammable anaesthetic gas connections with air, oxygen or nitro-
gen oxide.
• No calibration and no preventative checks or maintenance is to be carried out on this device.
• You cannot repair the device. The device contains no parts that you can repair.
• Do not make any changes to the device without the manufacturer's permission.
• If the device has been changed, thorough tests and checks must be carried out to ensure the continued
safety of further use of the device.
• Do not position the device in a location where it is difficult to disconnect it from the mains supply.
• Check the device before each use. Do not use the device if it is damaged in any way.
The continuous use of a damaged unit can be dangerous and may cause injury or improper results.
• The main material of the case is made of PC/ABS. Be cautious of potential allergic reactions to these ma-
terials.
Note on important information
Note
Manufacturer
Device in protection class 2
OFF / ON
IP21
Protected against solid foreign objects
12.5 mm in diameter and larger, and
against vertically falling drops of water
9