Technical Data; Ambient Conditions - Sentiotec O-A2-9 Instructions De Montage

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 58
Instructions for installation and use

13. Technical data

Ambient conditions

Storage temperature:
Ambient temperature:
Relative humidity:
Sauna control unit
Dimensions:
Switched voltage / three-phase 3N:
Frequency:
Contact rating of heater AC 1:
Switched current per phase of heater AC 1:
Min./max. input power:
Protection type (protected against jets of water):
Temperature adjustment range:
Connection to the mains supply as fixed wiring (fixed connection)
Light
Contact rating:
Fuse:
Thermal safety
Heater sensor with excess temperature fuse (139 °C shut-off temperature)
Automatically switches off after 6 hrs. (heating time limit)
Single sensor system with temperature sensor above the heater
Optional two-sensor system with temperature control over the bench.
WORLD OF WELLNESS
p. 26/28
-25 °C to +70 °C
-10 °C to +40 °C
max. 95%
240 x 220 x 90 mm
400 V
50 Hz
3 x 3 kW
13 A
4.3/6.3 VA
IP X4
+40 °C to +125 °C
100 W
1A T