9.6. Switching off the sauna control unit

To turn off the sauna control unit after using the sauna, press the ON/OFF
switch 7.
► The control lights 2 and 8 go out.

9.7. Extended periods of non-use

If you will not be using the sauna for an extended period of time, switch the main
fuse of the sauna control off in the fuse box.

9.8. How the optional door monitor works

During the preset time
If a person enters the sauna cabin while the timer is running, they might place
flammable objects on the cold sauna heater. Once the preset time begins, the
sauna heater begins to heat the cabin. Flammable objects on the sauna heater
ignite and cause a fire. The door monitor is meant to prevent this.
The preset time was set (see point 9.4).
► The timer is running and the sauna heater is not yet heating up.
The cabin door is opened.
► A recurring beep can be heard.
► The message "door" appears in the display 1.
► The preset time is cancelled.
► After the cabin door is closed, the preset time must be set again.
While the sauna heater is heating
The cabin temperature is below 40 °C, and the cabin door is opened.
► A recurring beep can be heard.
► The message "door" appears in the display 1.
► After the cabin door is closed, the sauna control unit must
be started again.