Wet Or Gel Battery Setting; Before Start-Up - Clarke RSW 37 Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

WET OR GEL BATTERY SETTING

According to the type of batteries (WET or GEL), set the machine electronic board and the battery charger, according to the
following procedure:
1.
Turn the ignition key (72) to "0".
2.
Open the hood (42) and engage the hood support rod (43).
Machine setting
3.
The machine factory setting is for lead (WET) batteries. If this setting corresponds to the type of batteries installed on the
machine, go to the next paragraph, otherwise perform the following procedures:
Disconnect the battery connector (45).
Remove the screws (83) and carefully remove the right control panel (84).
Remove the jumper wire (A, Fig. 1) from WET connectors (B) for lead batteries, and connect it to GEL connectors (C)
for gel batteries.
Carefully install the control panel (84) and the relevant screws.
Reconnect the battery connector (46).
Battery charger setting
4.
Turn the selector (52) to WET or GEL according to the type of batteries.
5.
Charge the batteries (see the procedure in the Maintenance chapter).

BEFORE START-UP

CAUTION!
Make sure that there are no open doors/hoods and that the machine is in normal operating conditions.
Make sure that the hopper (20) is properly closed.
If the machine has not been used after being transported, check that all the blocks used for the
transportation have been removed.
Operator's Manual - RSW 37
C
B
A
Figure 1
ENGLISH
S310201C