Belt Replacement - FOM INDUSTRIE SIKA PLUS Manuel D'emploi Et D'entretien

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

10.4 BELT REPLACEMENT (Figs. 10-05 / 10-06)
WARNING:
Disconnect the air system and lock the main switch off with a padlock before carrying out any parts
substitution.
Wear gloves.
Unscrew the two fastening screws and remove guard "A".
Loosen the four motor screws "B".
Pull out "C" and push the pulley in the direction of the arrow as far as belt "D" can be removed.
Insert the new belt stretching it with "C" until at point "E" there is a max. of 5 mm play on the belt.
Tighten screws "B" again and put guard "A" on again.
A
E
C
A1
D
55
GB
SIKA PLUS
10-05
B
B
10-06

Publicité

Table des Matières
loading

Table des Matières