Trouble
The motors do not work; no warning light turns on.
The machine does not move.
(Only for SCRUBTEC 545BL, 553BL and BOOST
5)
The warning lights (81) flash simultaneously.
The brush does not work, the red LED (81c) is on. The batteries are discharged.
The dirty water vacuuming is insufficient.
The solution flow to the brush is insufficient.
The squeegee leaves marks on the floor.
NOTE
If the machine has an optional battery charger installed, the machine cannot operate if the charger is not on board. In
case of battery charger malfunction, contact an authorised Service Center.
For further information refer to the Service Manual, available at any Nilfisk Service Center.

SCRAPPING

Have the machine scrapped by a qualified scrapper.
Before scrapping the machine, remove and separate the following materials, which must be disposed of properly according to the
Law in force:
Batteries
Brushes/pads
Plastic hoses and components
Electrical and electronic components (*)
(*)
Refer to the nearest Nilfisk Center especially when scrapping electrical and electronic components.
24
INSTRUCTIONS FOR USE
Possible Cause
The battery connector is disconnected.
The batteries are completely discharged.
The machine has been turned on by using
the ignition key and by keeping the switches
pressed.
The brush deck motor is overloaded.
The recovery tank is full.
The hose is disconnected from the squeegee. Connect.
The vacuum grid is clogged or the float is
stuck closed.
The squeegee is dirty or the squeegee blades
are worn or damaged.
The tank cover is not properly closed or the
gasket is damaged.
The solution filter is dirty.
The tank is dirty (the drain hole is clogged).
The Chemical Mixing System tank (optional)
is dirty/clogged.
There are debris under the squeegee blades.
The squeegee blades are worn, chipped or
torn.
The squeegee has not been adjusted with the
handwheel.
SCRUBTEC 545B / 545BL / 553B / 553BL / BOOST 5 - 9097054000
Remedy
Connect.
Charge the batteries.
Turn the ignition key to "0", then try to start the
machine again without pressing the switches.
Use a less aggressive brush suitable for the
floor to be cleaned or avoid working with extra
pressure function turned on.
Charge the batteries.
Empty the tank.
Clean the grid or check the float.
Clean and check the squeegee.
Close the cover or clean/replace the gasket.
Clean the filter.
Clean.
Clean with the drain cycle.
Remove the debris.
Replace the blades.
Adjust it.