Electronic Equipment; Safety Devices - EdilKamin KIKKA PLUS Installation, Usage Et Maintenance

Masquer les pouces Voir aussi pour KIKKA PLUS:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 54

• ELECTRONIC EQUIPMENT

ducted ventilation

SAFETY DEVICES

• SMOKE SENSOR:
Placed at the smoke outlet to detect the temperature.
Turns the stove on and off and controls its operation based on
defi ned parameters.
• PRESSURE SWITCH
Positioned in the fume-aspiration area, it is triggered in the
case of a depression in the fumes circuit (e.g. obstructed fl ue)
and interrupts the movement of the pellets.
It blocks pellet loading causing the stove to go out.
• SAFETY THERMOSTAT:
Trips when the temperature inside the stove is too high. It
stops pellet loading, causing the stove to go out.
GENERAL INFORMATION
socket
RS 232
Lithium
CR1632 ba-
ckup battery
Smoke-expulsion
motor
forced ventilation
screw
ingnition element
SERIAL PORT
The Dealer can install an optional on the AUX outlet for control-
ling the process of switching on and off (e.g. telephone remote,
local thermostat), located at the rear of the stove. This can be
connected via special optional trestle (code 640560).
BACKUP BATTERY
A backup battery is found on the control board (CR 1632
battery). Its malfunction is indicated with the following messa-
ges (not considered a defect but due to normal wear-and-tear):
"Battery check". For more detailed information, please contact
the DEALER who performed the fi rst 1st ignition.
FUSE *
Two fuses are inserted in the socket with switch, located on the
back of the stove, one of which operational * and the other is
held in reserve **.
- 32
-
**
*

Publicité

Table des Matières
loading

Table des Matières