Deleting The Memory Of The Individual Transmitter From The Control Unit's Memory; Complete Deletion Of The Radio Memory; Installing The Back-Up Battery; Installing The Solar Power System Kit Model Solekit - Nice ARIA200 Manuel D'installation Et D'utilisation

Motorisation pour portails battan
Masquer les pouces Voir aussi pour ARIA200:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

06. On the NEW transmitter, press and hold any key to be memorised for at least 5 seconds then release it.
Repeat the procedure for each transmitter to be memorised.
• Procedure with OLD transmitter memorised in Mode 2:
01. Draw near the control unit with the two transmitters:
02. On the NEW transmitter, press and hold the key to be memorised for at least 8 seconds then release it.
03. On the OLD transmitter, press and hold the key to be copied for at least 2 seconds then release it.
04. On the OLD transmitter, press and hold the key to be copied for at least 2 seconds then release it.
05. On the OLD transmitter, press and hold the key to be copied for at least 2 seconds then release it.
06. On the NEW transmitter, press and hold the key to be memorised for at least 5 seconds then release it.
Repeat the procedure for each transmitter to be memorised.

9.4 - DELETING THE MEMORY OF THE INDIVIDUAL TRANSMITTER FROM THE CONTROL UNIT'S MEMORY

This procedure allows for cancelling a single transmitter (memorised in Mode 1) or only one of its keys (memorised in Mode 2): it is neces-
sary to arrange the transmitter to be cancelled and simultaneously be able to access the control unit (before proceeding, open the gearmo-
tor – Fig. 9).
• Procedure with transmitter memorised in Mode 1:
01. On the control unit (Fig. 29) press and hold key P1 until the end of the procedure.
02. When led L1 lights up, while keeping key P1 pressed, also press and hold any key of the transmitter
to be cancelled, until led L1 flashes 5 times, then release both keys.
Repeat the procedure for each transmitter to be cancelled.
• Procedure with transmitter memorised in Mode 2:
01. On the control unit (Fig. 29) press and hold key P1 until the end of the procedure.
02. When led L1 lights up, while keeping key P1 pressed, also press and hold the key of the transmitter to be cancelled, until led L1 flashes 5 times,
then release both keys
Repeat the procedure for each transmitter to be cancelled.

9.5 - COMPLETE DELETION OF THE RADIO MEMORY

This procedure allows for cancelling ALL memorised transmitters: the procedure must be carried out on the control unit (before proceeding, open the
cover of the gearmotor – Fig. 9).
01. On the control unit (Fig. 29) press and hold key P1.
02. Check that led L1 lights up for 4/5 seconds, that it switches off then flashes 3 times.
03. Release key P1 precisely at the 3 rd flash.
04. Check that led L1 emits very fast flashes.
05. Check that led L1 emits 5 slow flashes = deletion completed.
9.6 - INSTALLING THE BACK-UP BATTERY (model PR100)
CAUTION! - The electrical connection of the back-up battery to the control unit must be made exclusively after completing all the
installation and programming stages, as the battery is an emergency power supply.
To install the back-up battery and connect it to the control unit, see Fig. 30 and consult the respective instruction manual.
When the automation is powered by the back-up battery, 60 seconds after a manoeuvre is completed the control unit automatically switches off the
ECSbus output (and all devices connected to it), the Flash output and all LEDs (with the exception of the ECSbus led, which flashes more slowly): this
automatic switching off is the "Standby" function.
Subsequently, when the control unit receives a command, the normal operating mode is restored with a short delay; this function is used to reduce
consumption (very important when the automation is powered by a battery)

9.7 - INSTALLING THE SOLAR POWER SYSTEM KIT model SOLEKIT

CAUTION! - When the automation mechanism is powered exclusively by the solar power supply system, IT MUST NOT BE POWERED
by the electricity grid at the same time.
To connect the SOLEKIT solar power supply system to the control unit, see Fig. 31 and consult the relevant instruction manual.
30
PR100
14 – English
wait 1 second between two successive steps.
31
SOLEKIT
2
1
29
1
2

Hide quick links:

Publicité

Table des Matières