Memory Function - Niko 05-715 Mode D'emploi

Masquer les pouces Voir aussi pour 05-715:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

05-715
light intensity. The intensity of the current that flows through the
circuit, determines the light level. If the input voltage lies below
the threshold voltage (±1.5V), the connected load will remain
off. If no input voltage is connected, the connected load lights
at min. light intensity. If the input voltage is 10V, the connected
load lights at max. light intensity.
After a power failure, the dimmer switches back on to its previous
value. See fig. 4 and 6.
Mode 3: 1-button mode
In 1-button mode, input 1 and input 2 have different and
independent functions. Input 1 functions as a 1-button dim
function, with or without memory. Input 2 allows light atmospheres
to be saved and retrieved at any time.
Operation input 1 (terminals 1 and 3): input 1 has a 1-button
operation mode. See fig. 1.

Memory function:

The dimmer can be used with or without memory. The is set to
1-button mode with memory function as a standard. To set the
dimmer without memory function, it suffices to keep the control
button pressed at max. light level for 10s. After 10s, the light will
decrease from max. to 50% to indicate that the memory function
is switched off. Immediately let go of the push button after this
change in light intensity! If you do not let go of the push button
immediately, there will be no changeover from 'with memory' to
'without memory' or vice versa. Repeat the procedure to reactivate
the memory function.