Mounting the controller
1. Make three holes in the wall as shown.
Outline of Remote
securing screw
wiring hole
securing screw
2. Run the cable between the controller and the
water heater or the controller and another
controller.
3. Remove the face plate from the temperature
controller using a screwdriver.
4. Connect the cable to the temperature controller.
5. Mount the controller to the wall using the holes
drilled in step 1.
6. Disconnect the power from the water heater.
7. Remove the plastic cover from the PCB and
electrical connections.
8. Thread the cable through the access hole at the
base of the unit and connect the wires to the
controller terminals on the right hand side bottom
of the PCB.
9. Secure the controller cable using the clamp
provided.
10. Replace plastic cover over PCB and then replace
the cover of the water heater.
Status Monitor
Remote Control
Cable
1-21/32"
3-5/16"
DIPSW 1
DIPSW 2
Cable Clamp
Remote Control
Connection Terminals
KCM Series Manual
Once Installation is complete, install the front panel
and cycle the unit on to ensure it is functioning
correctly. Proper installation/operation of the unit is
with the front panel installed.
45