Raise the fusing unit release lever, close the front cover and
then close the side cover by pressing the round projections
near the side cover open button. The misfeed (
go out and the start (
Raise the fusing unit release lever, close the front cover and
then close the side cover by pressing the round projections near
the side cover open button. The misfeed (
out and the start (
D: Misfeed in the SPF
An original misfeed may occur at one of three locations: if the misfed original is seen
from the original feeder tray, (A) in the original feeder tray; if the misfed original is not
seen from the original feeder tray, (B) in the exit area or (C) under the feeding roller.
Remove the misfed original following the instructions for each location.
(A) Open the feeding roller cover and pull the original gently to the left and out
from the original feeder tray. Close the feeding roller cover. Open and close
the original cover to clear the SPF misfeed (
original cannot be easily removed, proceed to (C).
) indicator will light up.
) indicator will light up.
) indicator. If the misfed
Feeding roller cover
) indicator will
) indicator will go