Les langues disponibles

6.8

Operating conditions

WARNING!
Danger of bursting from overpressure!
If the device explodes, there is a risk of serious injuries, chemical
burns, scalding!
▶ Do not exceed the maximum control and medium pressure.
Observe specifications on the type label!
▶ Observe permitted ambient and media temperature.
Ambient temperature for actuators:
Material
Actuator size ø
PA
175 mm / 225 mm -10 ... +50 °C
Medium temperature for body:
Body material
Stainless steel
PVC (see PT graph)
PVDF (see PT graph)
PP (see PT graph)
8
Temperature
Temperature
-10 ... +150 °C
-10 ... +60 °C
-10 ... +120 °C
-10 ... +80 °C
english
Type 2030, 2031, 2032,
Technical Data
Medium temperature for diaphragms:
The indicated medium temperatures apply only to media
which do not corrode or swell the diaphragm materials.
The behavior of the medium with respect to the diaphragm
may be changed by the medium temperature.
The function properties, in particular the service life of the dia-
phragm, may deteriorate if the medium temperature increases.
Do not use the diaphragms as steam shut-off element.
Material
Temperature
EPDM (AB)
-10...+130 °C
EPDM (AD)
-10...+143 °C
FKM (FF)
0...+130 °C
PTFE (EA)
-10...+130 °C
Advanced
-5...+143 °C
PTFE (EU)
Gylon (ER)
-5...+130 °C
Tab. 1:
Medium temperature for diaphragms
2033, 2037
Remarks
Steam sterilisation
up to +140 °C / 60 min
Steam sterilisation
up to +150 °C / 60 min
No steam / dry heat
up to +150 °C / 60 min
Steam sterilisation
up to +140 °C / 60 min
Steam sterilisation
up to +150 °C / 60 min
Steam sterilisation
up to +140 °C / 60 min