Standard Operation - Heating Mode - LG PREMTB10U Manuel D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

OPERATION INSTRUCTION
14

Standard Operation - Heating Mode

• Heating drive only operates on cooling and heating models.
• Heating doesn't operate on cooling only models.
• For option 2, when setting the desired temperature between 40-59 °F (4-15.5 °C), the in-
door unit shuts off if the indoor temperature is higher than the desired temperature.
• When using a central controller, a displayed value of the desired temperature may differ
depending on the function of the product.
• If indoor unit has 2set point function selected, unit will turn off thermal once the desired
set point is achieved.
Press
button to turn on the
1
indoor.
Press
button to select
2
Heating mode.
3
Adjust the desired temperature
by pressing
buttons.
When setting the desired
temperature lower than room
temperature, there is only
ventilation wind" should be "the fan
will blow room-temperature air.
h Setting temperature range:
Option 1: 60-86 °F (16-30 °C) (default setting)
Option 2: 40-86 °F (4-30 °C)