Technical data

Type
Rated voltage
Chain type
Nominal pressure
Nominal tractive force
Nominal locking force
Runtime-OPEN
Runtime-CLOSED
Service life
Housing
Protective system
Temp.range
Fire stability
Connection
Closing edge protection = deactivated
Locking relief = activated (retraction lift max. 0.2 mm)
Tandem Safety Function
For the operation of 2-3 drives on separate vents the
tandem safety function (TMS) may not be used! For
this the TMS line (yellow) of the connection cable
CDC-PC xxxx of the drives is disconnected, so that
the remaining drive(s) are still opened in case of fire
in the event of a failure, under voltage or overload
cut-out.
*
CDC-PC xxxx-T01
6/16
CDC 200/350
CDC 200/350
24 VDC, ±15%, 0,6 A
Standard chain
200 N + approx. 20% cut-off reserve
(temporary)
150 N safety cut-off force
approx. 1500 N
approx. 6,7 mm/s
approx. 5 mm/s
>10.000 double strokes
Aluminium pressure die casting
IP 50
-5 ... +75°C
30 min / 300°C
2,5 m silicone cable
*
* TMS line must
be disconnected!
English
CDC 200/350 -SBD
24 VDC, ±15%, 0,5 A
Side bow chain
150 N + approx. 20% cut-off reserve
(temporary)
Whenever two drives are operated on a single sash,
the tandem safety function can be used. This
function connects the cut-offs of the two drives in
such a way that if one drive is cut off due to overload,
the other drive will also be cut off.
In this case active jamming protection may not
activated!
CDC-PC xxxx-T01
99.823.30 2.3/09/13

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Cdc 200/350 sbd

Table des Matières