K Factors (In Pulse/L) Of The Fusion Spigots And Welding Sockets With Radius For Measuring Devices With A G2'' Nut - Burkert S020 Manuel D'utilisation

Masquer les pouces Voir aussi pour S020:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

6.5.7.
K factors (in pulse/l) of the fusion spigots and welding sockets with radius for
measuring devices with a g2'' nut
When the dimensions of the pipe are slightly different from dimensions d and s given in the table, recalculate the K factor using one of
the formulae in chap. 6.5.2.
If the measuring device does not automatically convert the K factor, use the following conversion formulae before setting the para-
meters of the device:
• K factor in pulse/US gallon = K factor in pulse/litre x 3.785
• K factor in pulse/UK gallon = K factor in pulse/litre x 4.546
Table 7: K factors, external diameters and theoretical cross sections of the welding sockets with radius, for measuring devices with a G2''
nut, and of the fusion spigots in plastic, used with a 8020, 8024, 8025 or 8026
measuring device inserted
material of the pipe
dn
50
65
80
100
110
125
150
180
200
250
300
350
400
18
8020, 8024, 8025, 8026
stainless
pe / pp
steel
13,0 (C)
-
7,86 (C)
8,32 (C)
5,52 (C)
5,49 (C)
3,20 (C)
3,51 (C)
-
-
2,00 (C)
2,66 (L)
1,32 (C)
2,12 (L)
-
-
0,72 (C)
0,98 (L)
0,50 (L)
0,63 (L)
0,35 (L)
0,42 (L)
0,26 (L)
0,30 (L)
-
0,23 (L)
English
external diameters and theoretical cross-sections
d
s
pVdf
steel
steel
[mm]
[mm]
-
60,3
2,0
5,53 (C)
76,1
2,9
3,65 (C)
88,9
3,2
2,34 (C)
114,3
3,6
-
-
-
-
139,7
4
-
168,3
4,5
-
-
-
-
219,1
6,3
-
273
7,7
-
323,9
9,5
-
355,6
10,1
-
-
-
Type S020
Technicaldata
d
s
d
pe/pp
pe/pp
pVdf
[mm]
[mm]
[mm]
-
-
-
75
6,9
75
90
8,2
90
110
10
110
-
-
-
140
12,8
-
160
14,6
-
200
18,2
-
225
20,5
-
280
25,5
-
315
28,7
-
355
32,3
-
400
36,4
-
s
pVdf
[mm]
-
2,5
2,8
3,5
-
-
-
-
-
-
-
-
-

Publicité

Table des Matières
loading

Table des Matières