Appendix 1: Technical Data - Dovre VIRTUS 50GA Installation Et Mode D'emploi

Masquer les pouces Voir aussi pour VIRTUS 50GA:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Appendix 1: Technical data

Model
VIRTUS 50 GA
Country
BE FR
Category
I2E+
Type of gas
G20/G25
Type of appli-
C11/C31/C91
ance
Nominal
8.5 kW
load (Hi)
Efficiency
83 %
Nominal out-
7 kW
put
Nominal gas
3
0.78 m
/hr(G20)
consumption
Initial pres-
20/25 mbar
sure
Burner pres-
12.5/19 mbar
sure
Code burner
320/220
nozzle
Pilot nozzle
312
code
Gas con-
3/8"
nection
Flue gas
exhaust
concentric
Weight
NOx
121 mg/kWh
NOx class
D OVRE
28
NL
GE LU
I2L/I2K
I2E
G25/G25,3
G20
C11/C31/C91 C11/C31/C91 C11/C31/C91 C11/C31/C91
8 kW
8.5 kW
81%
83 %
6.5 kW
7 kW
3
3
0.9 m
/hr
0.78 m
/hr
(G20)
(G20)
25 mbar
20 mbar
19 mbar
12.5 mbar
320/220
320/220
312
312
3/8"
3/8"
100mm/150mm
90 kg
91 mg/kWh
121 mg/kWh
5
Subject to change because of technical improvements
ES GB IE
GE
PT DK FI
SE IT AT
I2ELL
I2H
G25
G20
7.5 kW
8.5 kW
78 %
83 %
5.9 kW
7 kW
3
3
0.77 m
/hr
0.78 m
/hr
(G20)
(G20)
20 mbar
20 mbar
15.4 mbar
12.5 mbar
320/220
320/220
312
312
3/8"
3/8"
121 mg/kWh

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

50 gapVirtus 70ga

Table des Matières