Technical Data - Dovre 425 GA Installation Et Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

4 Technical data

Appliance
Gas type
Load
Nominal power
Gas use at
nominal power (15°C; 1013
mbar)
Pre-pressure
Burner pressure
Burner nozzle diameter
Pilot nozzle code
Chimney connection
Outlet protection
wijzigingen op grond van technische verbeteringen voorbehouden
725GA
725GAP
natural gas
butane/
propane
(G30/G31)
I2E+
I3+
10.0 kW
10.0 kW
9.0 kW
9.0 kW
1.1 m³/hr
0.30 m³/hr
(G20)
(G30)
20/25 mbar
29/37 mbar
(G20/G25)
(G30/G31)
15/19 mbar
28.5/36.5 mbar
(G20/G25)
(G30/G31)
2 x 2.0 mm
2 x 1.20 mm
51
30
100 mm
100 mm
Elmwood
Elmwood
100°C
100°C
425GA
425GAP
natural gas
butane/
propane
(G30/G31)
I2E+
I3+
7.0 kW
8.0 kW
6.0 kW
7.0 kW
0.75 m³/hr
0.25 m³/hr
(G20)
(G30)
20/25 mbar
29/37 mbar
(G20/G25)
(G30/G31)
3.7/4.7 mbar
27/35 mbar
(G20/G25)
(G30/G31)
2 x 2.50 mm
2 x 1.10 mm
51
30
100 mm
100 mm
Elmwood
Elmwood
100°C
100°C
27

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

425 gap725 ga725 gap

Table des Matières