36
Problem
Soot deposit on ther-
mocouple
Thermocouple faulty
No spark
Spark but no ignition
When ignition button is released, pilot flame goes out
Main burner does not ignite
Whistling between high and low setting
Disrupted flame effect
Gas smell
Smell of combustion gases in room
Appliance goes out
Remote control does not work
possible cause
Electromagnetic valve faulty Replace the control block (*).
Blocked pipes or nozzles
Burr on nozzle
Dirty burner
Gas leak
Blocked smoke exhaust
duct or air supply ducts
Appliance is leaking air
Dust on combustion cham-
ber
Empty batteries
Wiring to gas block
Faulty transmitter or
receiver
Clean the thermocouple with a cloth.
Replace the thermocouple (*).
possible solution
(*) = have installer carry out this action
Blow through the parts and clean them (*).
Remove the burr (*).
Clean the burner, check the placement of the logs,
remove any coal from the burner openings (*).
Close the main valve, find the gas leak and repair the leak
(*).
Check the ducts and clean them (*).
Check the door seals and appliance joints (*).
Clean the combustion chamber.
Replace the batteries.
Trace any bad contact point and repair it.
Replace the remote control.
Subject to change because of technical improvements