The machine is to be used only for its prescribed
purpose. Any other use is deemed to be a case of
misuse. The user / operator and not the
manufacturer will be liable for any damage or injuries
of any kind caused as a result of this.
4. Technical data
Power supply:
Motor rating in kW/HP:
Operating mode
Compressor speed in rpm:
Operating pressure in bar:
Pressure vessel volume in litre:
Theoretical intake rate in l/min.:
Sound power level L
in dB:
WA
Sound pressure level L
in dB:
pA
Protection type:
Machine weight in kg:
Operating mode S3 - 25% - 10min: S3 = Intermittent
mode without influencing the starting process. This
means that during a period of 10 min the max.
operating time is 25% (2.5 min).
5. Points to note when setting up the
compressor
Examine the machine for signs of transit
damage. Report any damage immediately to the
company which delivered the compressor.
The compressor should be set up near the
working consumer.
Avoid long air lines and long supply lines
(extensions).
Make sure the intake air is dry and dust-free.
Do not set up the compressor in damp or wet
rooms.
The compressor may only be used in suitable
rooms (with good ventilation and an ambient
temperature from +5°C to +40°C). There must be
no dust, acids, vapors, explosive gases or
inflammable gases in the room.
The compressor is designed to be used in dry
rooms. It is prohibited to use the compressor in
areas where work is conducted with sprayed
water.
18.08.2008
9:53 Uhr
6. Assembly and starting
Important!
You must fully assemble the appliance before
using it for the first time.
6.1 Voltage
The compressor is equipped with a mains cable with
shock-proof plug. This can be connected to any
230V ~ 50Hz shock-proof socket which is protected
by a 16 A fuse. Before you use the machine, make
230 ~ 50 Hz
sure that the mains voltage complies with the
1.1/1,5
specifications on the rating plate. Long supply
S3 25% 10 min
cables, extensions, cable reels etc. cause a drop in
3550
voltage and can impede motor start-up. In the case
of low temperatures below +5°C, motor start-up is
8
jeopardized as a result of stiffness.
6
180
6.2 On/Off switch (8)
94.6
To switch on the equipment set the On/Off switch (8)
to position 1.
74.6
Move the On/Off switch (8) to position 0 to switch off
IP 20
the equipment.
11.6
6.3 Adjusting the pressure: (Fig. 1)
You can adjust the pressure on the pressure
gauge (6) using the pressure regulator (7).
The set pressure can be taken from the quick-
lock coupling (5).
6.4 Setting the pressure switch
The pressure switch is set at the factory.
Switch-on pressure 6 bar
Switch-off pressure 8 bar
6.5 Quick-release coupling (5)
Connect
Push the nipple on your compressed air hose into
the quick-release coupling, the sleeve will
automatically spring forwards.
Disconnect
Pull back the sleeve and remove the hose.
Important. As you release the hose coupling,
hold the hose coupling part in your hand to
prevent injuries caused by the hose being thrown
backwards.
The compressed air hose is also fitted with a quick-
lock coupling to which accessories can be connected
as described above.
6.6 Compressed air hose
For connecting to a compressed air source.
Seite 13
GB
13