IMPORTANT: The instruction manual you are holding includes essential information on the safety measures to be
implemented for installation and start-up. Therefore, the installer as well as the user must read the instructions before
beginning installation and start-up.
Keep this manual for future reference.
To achieve optimum performance of the Mini light for rapid installation, follow the instructions provided
below:
1. VERIFY THE CONTENTS OF THE PACKING:
The following accessories are included inside the box:
Mini light for rapid installation 33708 - 33684
Floodlamp unit
Installation and maintenance manual
2. GENERAL CHARACTERISTICS:
This floodlamp has been designed to be used fully submerged underwater in fresh water SPAS. It is a Class
III electric apparatus with very low safety voltage (12 V with alternating current).
The floodlamp complies with IPX8 degree of protection (resistance to penetration of dust, solid bodies and
humidity) at a nominal immersion depth of 2 m.
This floodlamp complies with international safety standards for lights, especially the EN 60598-2-18
standard: LIGHTS PART 2: SPECIFIC REQUIREMENTS SECTION 18 LIGHTS FOR SWIMMING POOLS AND
SIMILAR APPLICATIONS.
The manufacturer is not responsible in any circumstances for assembly, installation or start-up of any
electric components which have been inserted or handled at locations other than its own premises.
3. INSTALLATION:
• Never install in vertical position with the lamp facing downwards.
• Ensure that the voltage the lamp receives is never greater than 12 V. The current must be supplied by an
S.E.L.V. transformer and protected by a correctly rated E.L.C.B. (Fig. 1).
• In order to clearly light a pool it is recommended to install a 50W floodlamp every 10 m
In swimming pools which are especially deep, a 50 W floodlamp is required for every 20 m
volume.
• In order to prevent glare, the floodlamps should be installed so that they face away from the residence or
usual view of the swimming pool.
• In the event that lighting is used in training or competition pools, the floodlamps should be installed on
the sides to prevent glare on the swimmers.
• To avoid the need to empty the pool to change the lamp, we recommend that the floodlamp be installed in
areas which are accessible from the upper edge of the pool.
Prior to installation verify that the gland seal has been fully tightened.
4. ASSEMBLY:
This light is manufactured for installation in concrete swimming pool and SPAS or guiding tube.
1. Install the wall conduit in the concrete wall, at a distance of 400-700 mm. Below the water level (Fig.
2).
2. The wall conduit must be extended with a cable conduit the lenght of which remains above the
maximum level of the swimming pool or spa. (Fig. 3).
3. Feed the light cable through the conduit. (Fig. 4).
4. Then fit the light itself, pushing it into place. (Fig. 5).