Installer Checklist - Thermador Professional PCG24 Manuel D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Flame Adjustment (if necessary)
Tube-style gas burners used in Thermador appliances
have air shutter systems which are similar to the illustration
in Figure 14, and can be adjusted using the following
method (unless adjustment is not recommended). It is
necessary to remove the burner from the appliance in order
to perform air-shutter adjustments.
Loosen shutter screw(s) and turn shutter to new
position.
Adjust the shutter to more-closed position if the flame
is lifting or blowing, or is not carrying over.
Adjust the shutter to more-open position if the flame is
too yellow. (See Figure 14.)
Retighten the shutter screw(s).
After adjustment, reinstall the burner and perform
flame evaluation. The air shutter must fit over the
orifice hood for proper operation of the burner.
Repeat procedure as needed until flame characteristics
are acceptable. (See Figure 13.)
More Open:
Less Yellow Flame
More Closed:
Less Blue Flame
More Carryover
Less Lifting or Blowing
Figure 14: Air Shutter Adjustment (if necessary)
WARNING
Burner adjustments must be performed by a
qualified technician. Improper adjustments may
cause harmful by-products or void the
appliance's warranty.
Allow burners to cool before attempting to
remove them!
Call Thermador if:
1. Any of the burners do not light.
2. Any of the burners continue to burn yellow.
Screw
Air
Shutter

Installer Checklist

Final Check List
Cooktop correctly positioned in countertop recess.
Specified clearances maintained to cabinet surfaces.
Burner caps positioned properly on burner bases.
All packaging material removed. (NOTE: Wok models
have tie-down straps around the burner, which must be
removed before using the appliance.)
Island Trim or Backguard attached according to
instructions.
The griddle/ grill plate tilted slightly forward. (See "Grill/
Griddle Tilt Adjustment (not all models)" on page 11.)
Gas Supply
Connection: 1/2" NPT with a minimum 3/4" diameter
flex line.
If converting from natural to LP gas, refer to LP
Conversion Instructions for details.
Manual gas shut off valve installed in an accessible
location (without requiring removal of appliance).
Unit tested and free of gas leaks.
Electrical
For models with the 12" electric griddle, a polarized
and grounded 120VAC receptacle with 15 AMP over
current protection is provided for service cord
connection.
For models with the 24" electric griddle, a properly
grounded, 240 VAC service connection with 30 AMP
over current protection is provided.
Operation
All internal packing materials removed. (Check below
grates and grill pans.)
Bezels centered on burner knobs, and knobs turn
freely.
Purge air from gas system by operating one of the top
burners for several minutes.
Each burner lights satisfactorily, both individually and
with other burners operating.
Burner grates are correctly positioned.
Installer
Give CARE and USE MANUAL and INSTALLATION
INSTRUCTIONS to your customer.
English 15

Publicité

Table des Matières
loading

Table des Matières