Underlay for the lock body
The lock body underlay allows for a more favourable assembly position of the wall cover plates
to be achieved, as these can be mounted in a more stable area of the doorframe / wall as a
result(Fig. 30a).
Note: to determine the cylinder length required, the underlay thickness of 18 mm must be
added to the existing thickness of the door leaf.
Fig. 30
Fig. 30a
Fig. 30b
Mounting plate ASP17
The ASP17 mounting plate is suitable for the sturdy fixing of lock casings. It is used, in particular,
when the options for anchoring the reinforced door bar lock casings directly and securely to the
subsurface are inadequate. (Fig. 31, see separate installation instructions ABUS ASP17).
Fig. 31