Special accessories
PWA2700
Note: An embrasure breadth of at least 86 cm is required for embedding into the wall on
both sides (doorway 90 cm).
• When using the PWA2700, first remove the plastic plug from the door bar casing (if
necessary lever through the small hole with a screwdriver / Fig. 25).
• Insert the door bar end piece with round bolts and tighten with the screw of accessory
article PWA2700 (Fig. 26).
• Mount the wall strike plate onto the round bolts.
• Lock the door bar onto the wall until the end stop. Mark out the attachment points (1.) of
the wall strike plate. Close back the door bar (Fig. 27).
• Pre-drill the attachment points for the wall strike plate with Ø 6 mm, insert the dowel
and screw (Fig. 27).
• Drill through both of the external mounting holes (2.) with Ø 10 mm, and a depth of at
least 140 mm. Insert the complete dowel with the screw and tighten (Fig. 27).
• Drill out the holes for the connecting bolts (3.) with Ø 14–16 mm, width a depth of 70 mm
(Fig. 27). Press down the plastic cover.
Fig. 25
Fig. 27
48
2.
1.
3.
3.
2.
1.
2.
Fig. 26
1.