Special Accessories - Abus PR2700 Notice De Montage Et D'utilisation

Barre transversale blindée
Masquer les pouces Voir aussi pour PR2700:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Special accessories

PWA2700
Note: An embrasure breadth of at least 86 cm is required for embedding into the wall on
both sides (doorway 90 cm).
• When using the PWA2700, first remove the plastic plug from the door bar casing (if
necessary lever through the small hole with a screwdriver / Fig. 25).
• Insert the door bar end piece with round bolts and tighten with the screw of accessory
article PWA2700 (Fig. 26).
• Mount the wall strike plate onto the round bolts.
• Lock the door bar onto the wall until the end stop. Mark out the attachment points (1.) of
the wall strike plate. Close back the door bar (Fig. 27).
• Pre-drill the attachment points for the wall strike plate with Ø 6 mm, insert the dowel
and screw (Fig. 27).
• Drill through both of the external mounting holes (2.) with Ø 10 mm, and a depth of at
least 140 mm. Insert the complete dowel with the screw and tighten (Fig. 27).
• Drill out the holes for the connecting bolts (3.) with Ø 14–16 mm, width a depth of 70 mm
(Fig. 27). Press down the plastic cover.
Fig. 25
Fig. 27
48
2.
1.
3.
3.
2.
1.
2.
Fig. 26
1.

Publicité

Table des Matières
loading

Table des Matières