Inventum IVW6015A Manuel D'utilisation page 50

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Problem
FAULT CODES
The fault codes are shown on the display of the control panel.
Fault code
Possible cause
FF
There is insufficient water supply.
F5
There is no water pressure.
F3
The water supply does not stop.
F2
The waste water in the appliance cannot
be discharged.
F8
The heater has an error.
F1
The safety for water overflow is
activated.
FE
There is an electronic error.
F7
The temperature of the appliance is too
high.
F9
The position of the distributor has an
error.
F6
The heat sensor has an error.
HI
There is a high voltage error.
LO
There is a low voltage error.
50
English
Possible cause
The level of salt consumption is set
too high.
The cap of the salt reservoir is not
closed correctly.
Any spilled salt during filling of the
salt reservoir was not cleaned
immediately.
The water supply is polluted.
Possible solution
Make sure that the water tap is fully open and that
the water supply is not blocked.
Close the water tap, remove the water inlet hose and
do a check if the hose is clogged.
Start the appliance again.
Contact the Inventum-servicedienst if the fault code
keeps re-occuring.
Contact the Inventum-servicedienst.
Close the water tap.
Contact the Inventum-servicedienst.
Do a check if the drain hose is clogged.
Do a check if the filters are clogged.
Switch the appliance off and reset the program. Refer
to section
Contact the Inventum-servicedienst if the fault code
keeps re-occuring.
Contact the Inventum-servicedienst.
Contact the Inventum-servicedienst.
Contact the Inventum-servicedienst.
Contact the Inventum-servicedienst.
Contact the Inventum-servicedienst.
Contact the Inventum-servicedienst.
Contact the Inventum-servicedienst.
Contact the Inventum-servicedienst.
Possible solution
Adjust the level of salt consumption.
'Setting the level of
Refer to section
salt consumption'
.
Make sure that the cap of the salt
reservoir is closed firmly.
Make sure that you clean any spilled
salt immediately and run a full
program to prevent corrosion.
Do a check on the water supply.
'Resetting the program'
.

Publicité

Table des Matières
loading