Application; Technical Specifications - Franke AQCT0071 Notice De Montage Et De Mise En Service

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

• The battery compartment with battery or power supply with extension cable must
be ordered separately (see Accessories,
• All work must be carried out in a de-energised state.
• We reserve the right to make changes.
5.

Application

AQUACONTACT - a shower panel made of MIRANIT-S solid-surface material for
wall mounting with electronic timer, for battery or mains power, with a DN 15
thermostat battery. For connection to hot and cold water supply.
30 second flow time.
With a device for an optional bypass solenoid valve cartridge for carrying out thermal
disinfection, with the option of manual thermal disinfection.
With integrated hygiene flush (24h after last actuation, for 10s). Functions which can
be activated via reflection code on sensor: Activation/deactivation of hygiene flush
and cleaning switch-off (3 min.).
Additional functions via optional remote control
– Setting the flow and interval times
– Switch from time control to body reflection, maximum flow time of 300 seconds
– Program-controlled thermal disinfection with safety switch-off
6.

Technical specifications

Minimum flow pressure:
Recommended flow
pressure:
Maximum operating
pressure:
Calculated flow rate:
Volumetric flow:
Fitting:
Bypass:
Flow duration:
Operating voltage:
Power consumption:
Protection class:
Chapter
1.0 bar
1-5 bar
10 bar
0.15 l/s
0.15 l/s
0.20 l/s at a flow pressure of 3 bar
0.06 l/s at a flow pressure of 3 bar
30 s
6 V DC
1.5 W
IP 67
- 5 -
30).

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Aqct007476129822191157612982219085

Table des Matières