1.3 INDIVIDUAL PROTECTIVE DEVICES (IPD) TO BE USED

When handling the product, especially if already installed, always wear the following items of protective clothing: Accident-
prevention shoes, safety goggles, accident-prevention gloves and a leather apron or similar form of protection.
Every time maintenance or repair operations are performed on installed electric pumps, particularly those which are immersed in
dangerous liquids or septic tanks, all parts must be thoroughly cleaned and washed with water or specific products.

2 . DEVICE IDENTIFICATION

A metal identification plate stating all the product specifications is applied to the electric pump. Refer to the data on this plate when
seeking information or clarifications.

2.1 ATEX MARKING (potentially explosive environment)

0575
According to EN 60079-0 the plate coding summarises the following:
The symbol shown is in conformity with Annex X of Directive 94/9/CE and identifies that the product meets the
essential health and safety requirements laid down by that directive.
0575
identification number of the organisation undertaking the production control
Specific symbol of the ATEX Directive 94/9/CE, shown in Annex II of the Directive
II
Group to which the appliance concerned belongs. Group II applies to equipment NOT used in mining
2
category of the appliance to be certified (products designed for operation in zone 1)
GD
explosive atmospheres permissible around the equipment may be in the form of gases, vapors and dusts and mists.
EX
Ex symbol for electrical equipment for use in potentially explosive atmospheres required by technical legislation
db
the electrical protection mode used for the device corresponds to confinement in a flameproof enclosure - electrical
apparatus suitable for zone 1.
k c
the mechanical protection mode used for the device corresponds to that of protection for immersion in liquids and
for construction safety
IIB
class of gas for which the equipment is suitable
IIIC
class of dust for which the equipment is suitable (combustible dust)
tb
protection of electrical construction with enclosure for dust - electrical apparatus suitable for zone 21
T5
The maximum surface temperature of the apparatus (T5 = 100°C)
T100°C
indicates the maximum surface temperature
IP 68
protection class

2.2 PLATE

The electric pump is fitted with a plate bearing the following information:
- Homologation EX (II 2GD Ex dkc IIB T5 tD A21 T100°C IP68 X);
- certificate number: DNV-MUNO.0496.ATEX.07/3450 X;
- Pump type (NAME);
- Version (accessories installed and mechanical sealing materials);
- Voltage rating;
- Current absorbed from the mains;
- Power absorbed by the pump;
- Frequency;
- Power factor;
- Rotation speed;
- Degree of protection of the casing: IP68 (declared by the manufacturer);
- Rated capacity;
- Rated head;
- Number of strokes;
- Insulation class;
- Max. immersion depth;
- Year of construction and serial number;
- Service factor S1 with casing covered, S3 (25%) with motor floating;
S1 = only with motor fully submerged or using the cooling jacket
S3 = with the hydraulic part submerged and the motor floating

3 TECHNICAL CHARACTERISTICS

The electric pump specifications are stated on the metal plate and on the packaging.
Pump body and rotor in EN-GJL-250 cast iron, remaining parts in EN-GJL-250 cast iron (UNI EN 1561 - 1563).
II 2 GD Ex db k c IIB T5 Ex tb IIIC T100°C IP68