FIRE SAFETY MEASURES
While installing the appliance, it is necessary to respect the following safety measures:
a) In order to ensure sufficient thermal insulation, respect the minimum safety distance from objects or furnishing
components flammable and sensitive to heat (furniture, wood sheathings, fabrics. etc.) and from materials
with flammable structure (see Picture 2). All the minimum safety distances are shown on the product
data plate and lower values must not be used .
b) In front of the hearth, in its radiation area there must not be any flammable object or construction material
sensitive to the heat at least within 100cm ; This distance can be reduced to 40 cm if you will install in front of
the element to protect a retro ventilated and heat resistant protection.
The product must work exclusively with inserted ash drawer.
Solid combustion residuals (ashes) must be collected in an air-tight and fire-resistant container. The appliance must
never be switched on when there are gaseous emissions or vapours (for example glue for linoleum, gasoline etc.). Do
not deposit flammable materials close to the same.
During the combustion will be spread thermal energy which warms up the surfaces, the door, the fireplace glass, the
handles and knobs, the smoke pipe and the front side of the stove. Please avoid the contact of these parts without
gloves or the relevant tools.
Protection of the floor with
incombustible material.
Flooring in
combustible material.
Warn children of the danger and keep them away during the operation of the stove.
The use of a wrong or wet fuel causes the formation of creosote deposits in the flue and will fuel a chimney fire.
4.1. FIRST-AID MEASURES
Should any fire arise in the stack or in the flue:
a) Close the feeding door and the ash drawer door .
b) Close the registers of combustion air
c) Extinguish the fire using carbon dioxide fire-fighting means (CO
d) Seek immediate intervention of FIRE BRIGADE.
DO NOT EXTINGUISH FIRE USING WATER JETS
When the fire has been extinguished, let the flue check by an expert to find possible cracks and permeable points.
5.

FLUE

Essential requirements for a correct operation of the device:
the internal section must be preferably circular;
be thermally insulated and water-proof and produced with materials suitable to resist to heat,
combustion products and possible condensates;
not be throttled and show a vertical arrangement with deviations not greater than 45° ;
if already used, it must be clean;