OPERATION

Connect the gas hose to the gas connector.
Please note:
-
The gas hose is NOT included with the heater. Hose must be purchased sepa-
rately
-
Minimum / Maximum length gas hose: 60-80 cm
-
Gas connector suitable for:
- Ø 8-12 mm hose (all EU countries except France)
- G1/2'' (France only)
For gas hose with threaded connectors: bind 2 or more rounds of plumbing
tape around the gas pipe before connecting the gas hose for security.
Bind 2 or more rounds of Teflon plumbing tape around the gas burner inlet
connector and connect the gas pipe. Use a wrench to tighten the connection.
Connect the other end of your gas hose according to the mounting instruc-
tion as supplied with the gas hose and/or supplied with the gas regulator see
picture 9.
Note:
-
The gas hose is NOT included with the heater
-
The gas regulator is not included with the heater
Connect the regulator to the gas cylinder (not included) according to the
mounting instruction as supplied together with the gas regulator and/or the
gas cilinder
Put gas cylinder on the base.
WARNING! Ensure the hose does not contact any high temperature surfaces, or
it may melt and leak causing a fire. After the cylinder is placed inside the heater,
secure the cylinder with block belt tightly. The heater must be fixed on a stable
and strong table with a minimum height of 40cm from floor level.
TO TURN ON THE HEATER
Check that the regulator seal is correctly fitted and able to fulfil its function
Before starting, always do a leak test. See section "leak testing".
1.
See picture 11
2.
Make sure the turnable knob at right hand side is in 'off' position
3.
Fully open the gas cylinder – make sure that gas can flow unhindered towards
heaters
4.
Press and turn knob B to "PILOT" position.
5.
Press down knob B and hold it pressed for 60 seconds. While keeping knob B
pressed, press ignitor button A several times until the pilot flame inside the
heater lights. Make sure to keep pressing knob B for 20-40 seconds after pilot
flame is lit.
6.
20-40 seconds after pilot flame is lit: release knob B and stop pressing ignitor
button A
7.
Now turn the knob B to 'HIGH" position and leave it there for 5 minutes or
more before turning the knob to the desired temperature position.