STOPPER CONTROL BOARD
1. INTRODUCTION
STOPPER is a control unit dedicated to the movement of the chain barrier with 24Vdc motor.
The coexistance of various types of safeties such as the control of the absorbed power by
the motor and the velocity of the motor allows a rapid intervention of the anti - squeezing
security (sense).
Through the encoder present in the motor it is possible to control the exact position of the
chain and to use it without mechanical limit switches.
2. CONFIGURATION
Use this point to connect
the motor's casing to the
control panel and to the
ground.
Jumper (if present)
in order to invert the
motor phases
Connector for the
battery charger ACG5482
3. ELECTRICAL CONNECTIONS
Terminal Function
1-2
Flashing signal output
3
Positive power supply TX & RX photocell
4
Negative power supply TX photocell
5
Negative power supply RX photocell and common button
and safety
6
STOP of the chain raising
7
STOP of the chain lowering
8
STOP button input
9
RX photocell contact input
10
Pedestrian button input
11
Step by step button input
12
Not to use
13
Not to use
Example of connection
CABLE
MOTOR CASING
OF EARTH
CONNECTION
CONTROL UNIT
IMPORTANT: to obtain a correct working of the accessories (photo devices in particular)
connected to the control box, it is very important that the entire system (motor+ control box)
has a single mass reference system.
Automatic
chain lifting
Motor/Encoder Connector
Setting
Out: 24 Vac 25W MAX
Out: +24Vcc
150mA MAX
Out: GND TX
Out: GND RX Common
Normally closed (NC)
Normally closed (NC)
Normally closed (NC)
Normally closed (NC)
Normally open (NO)
Normally open (NO)
Any contact which is
Normally Closed (N.C.)
MOTOR CASING
Must be bridged to the
FIXTURE SCREWS
common if not used.
CONNECTION
CABLE
The control unit has inputs for mechanical limit switches, for the step by step button, for the
pedestrian opening, for the safety photocells and the output for flashing light 24 Vac.
The unit also allows the regulation by trimmer both the automatic chain lifting and the motor
force.
Action can control motors at 24 - 30 Vcc with a maximum consumption of 7A.
Photocells
Power supply
150mA MAX
You must therefore connect a small cable between the motor casing and the control box at
the point shown in the figure. If there is a good ground connection it is advisable to connect
it to the system.
22
Setting maximum
torque threshold
Buttons:
1 = yellow
2 = Blue
3 = Red
Manual selector (Left) / automatic
(Right)
Motor/ Encoder Connector.
Encoder +5Vcc (brown)
Signal (green)
GND (white)
Motor