REMEDY IN CASE OF FAULTS

TYPE OF MALFUNCTION WHAT ELSE?
Unit does not start
Unit does not suck in
Unit does not gener-
ate pressure
52
POSSIBLE CAUSE
Multifunction switch
No voltage applied
can not switched on
Unit fuse has triggered
Multi-function switch not
set back previously to „0"
Air bubbles do not exit
Inlet valve clogged
at the return hose
Inlet/outlet valve soiled
/ foreign bodies (e.g.
threads) drawn in / worn
Pressure control valve
turned down completely
Air bubbles exit from
Unit is sucking in outside
the return hose
air
Unit has sucked in
Air in the oil circuit
Unit reached pres-
Suction filter clogged
sure, but the pressure
collapses, also at the
pressure gage, during
spraying.
Paint cannot be worked in
this state. Due to its prop-
erties the paint clogs the
valves (inlet valve) and the
delivery rate is too low.
Unit reached pressure,
Clogged filter do not let
but the pressure col-
enough paint pass
lapses during spraying.
pressure gage still
shows high pressure
Tip clogged
Unit does not generate
Relief valve defective
the max. pressure pos-
sible. Paint neverthe-
less exits at the return
hose.
Super Finish 23 Select
MEASURES FOR ELIMINATING THE MALFUNCTION
Check voltage supply
Let the motor cool down
Set multi-function switch to „0" and then
switch back on
Press the inlet valve button until the stop is
reached several times by hand
Remove the valves and clean then (-> refer to
Section Pkt.10.2/10.3) / replace worn parts
Turn the pressure control valve to the right un-
til the stop is reached
Check: Suction system tightened properly?
Inlet valve button leaky? -> Replace wiper and
O-ring (-> refer to Section 10.1)
The red entry is missing in the coating mate-
rial entrance (-> see 4.1)
Bleed the oil circuit in the unit by turning the
pressure control valve completely to the left
(until overturning) and let it run approx. 2 – 3
min. Then turn the pressure control valve to
the right and set the spraying pressure (repeat
process several times, if necessary). Process is
assisted by positioning the unit vertically.
Check the suction filter. If necessary, clean/
replace
Dilute the paint
Check/clean the (high-pressure filter) gun filter
Clean the tip (-> refer to Section 10.1)
Please contact Wager Customer Service