Fuse Check/Replacement/Reset; Troubleshooting; Scrapping - Clarke Vantage 14 Mode D'emploi

Masquer les pouces Voir aussi pour Vantage 14:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

ENGLISH

FUSE CHECK/REPLACEMENT/RESET

Drive the machine on a level loor.
1.
2.
Turn the knob (32) to "0" and disconnect the battery (7).
3.
Open the cover (4) and check one of the following fuses
for deactivation or integrity:
(A, Fig 7): F1 (30 A) circuit breaker, brush motor.
(B): F3 (5 A) blade fuse, accessories.
(C): F2 (30 A) blade fuse, vacuum system motor.
Reset any deactivated fuse, when the component that
caused deactivation has fully cooled down.
NOTE
If fuse reset or replacement does not restore
operation, refer to Service Manual or contact Clarke
4.
Close the cover (4).

TROUBLESHOOTING

Trouble
The motors do not turn on; no warning
light turns on.
The brush motor does not run.
The vacuum system motor does not
turn on.
The dirty water vacuuming is
insuficient.
The solution low is insuficient.
The squeegee leaves marks on the
loor.
For further information refer to the Service Manual, available at any Clarke Service Center.

SCRAPPING

Have the machine scrapped by a qualiied scrapper.
Before scrapping the machine, remove and separate the following materials, which must be disposed of properly according to the
Law in force:
Battery
Brushes
Plastic hoses and components
Electrical and electronic components (*)
(*)
Refer to the nearest Clarke Center especially when scrapping electrical and electronic components.
18
Possible Cause
The battery connector is disconnected.
The battery is fully discharged.
The F3 fuse is blown.
The F1 fuse has triggered.
The F2 fuse is blown.
The recovery tank is full.
The vacuum grid is clogged or the loat is closing.
The vacuum hose is disconnected from the squeegee
or faulty.
The squeegee is dirty, or the squeegee blades are
worn or damaged.
The recovery tank cover is not properly closed, or the
gaskets are damaged.
The vacuum system motor ilter is dirty.
The detergent duct is dirty/clogged.
There is debris under the squeegee blades.
The squeegee blades are worn, chipped or torn.
Figure 7
Remedy
Connect.
Charge.
Replace.
Reset the fuse.
Replace.
Empty.
Clean the grid and check the loat.
Connect.
Clean the squeegee or replace the blades.
Check and/or clean the seating surface or replace
the gaskets.
Clean.
Clean.
Remove the debris.
Replace the blades.
Instructions For Use - VANTAGE 14
B
A
C
P100414

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

9087305020

Table des Matières