VOLTCRAFT VC-420 Mode D'emploi page 58

Multimètre numérique
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Resistance
Range
600.0 Ω
6.000 kΩ
60.00 kΩ
600.0 kΩ
6.000 MΩ
60.00 MΩ
Overload protection 1000 V
Capacity
Range
40.00 nF
400.0 nF
4.000 µF
40.00 µF
400.0 µF
4000 µF
Overload protection 1000 V
Frequency "Hz" (electronic)
Range
9.999 Hz
99.99 Hz
999.9 Hz
9.999 kHz
99.99 kHz
999.9 kHz
9.999 MHz
Signal level max. 15 Vrms
58
Resolution
0.1 Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ
Resolution
0.01 nF
0.1 nF
0.001 nF
0.01 µF
0.1 µF
1 µF
Resolution
0.001 Hz
0.01 Hz
0.1 Hz
0.001 kHz
0.01 kHz
0.1 kHz
0.001 MHz
Accuracy
±(1.2% + 5)
±(2% + 20)
Accuracy
±(3% + 5)
±(5% + 5)
Accuracy
±(0.1% + 5)

Publicité

Table des Matières

Dépannage

loading

Ce manuel est également adapté pour:

1405087

Table des Matières