Installation and start-up
7.1.2

Connecting the start signal cable

In cases where a foot switch is used as the start signal transmitter, the cables are already
supplied with the appropriate plugs.
If connection to a control system is required, the customer will have to put the plugs
together.
Connection plug, seen from cable side:
Fig. 5: Connection plug, seen from cable side:
1
Start signal
2
Alarm output
(max. 24 V AC/DC / 2 A)
3
EARTH (for start signal)
7.1.3

Setting of display contrast

The display contrast can be changed by inserting a screw-driver in a hole in the housing
base, and turning.
7.1.4

Compressed air connection

CAUTION!
The required valve control pressure must be at least 0,5 MPa (5 bar).
The compressed air must be free of moisture and oil, otherwise the
features of the glues would be significantly modified.
417101357 Rev. 3-05.2019
4
Common (common connection to alarm output and
'completed' message)
5
'Completed' message
(max. 24 V AC/DC / 50 mA)