10
Technical data
Data
Power supply
Power supply
Capacity
Protective class
Fine-wire fuse
Internal fuse protection 125 mA for
Internal fuse protection 250 mA for
Safety type (casing)
Applicator time setting in steps of 0,01 sec.
Rotor spray - running-down time in steps
of 0,01 sec.
Rotor spray rotational speed
Compressed air supply
Product pressure range
Rotor spray voltage signal
Start signal floating contact or transistor (max.)
Reserve signal
(Capacitive key with make contact function)
Empty signal
(Capacitive key with make contact function)
Rotor spray control, pulse-width modulation
Collective fault indication, floating (max.)
'Completed' indication, floating (max.)
Dimensions (w x h x d)
Housing material
Weight
CAUTION!
Compressed air must be clean, dry and oil-free. Exceeding or underflow of
the supply pressure can impair the function.
6000 or 9000 (rpm)
0,5 (5) – 0,75 (7,5) MPa (bar)
0 - 0,16 (1,6) /
0 - 0,38 (3,8)
300 x 114 x 200 mm
Polystyrene;
varnished with
29
Technical data
Value Unit
50/ 60 Hz
230 /115 V AC
25 W
II
5 x 20 mm
230 V
115 V
32 IP
0,01 - 99,99 sec.
0,00 - 99,99 sec.
MPa (bar)
0,56 / 1 000 (V / rpm)
24 / 5 V / mA
pnp
pnp
24 / 6 V DC/W
24 / 2 V AC/DC/A
24 / 50 V AC/DC/mA
acrylic paint
2,7 kg
417101357 Rev. 3-05.2019