Duct Mounting

Before beginning Duct Mounting:
I have confirmed local codes for proper draining practices for hot water
I have chosen an installation location that meets the requirements on page 4
Follow these steps to mount TrueSTEAM directly to the supply duct of the homeowner's HVAC equipment.
STEP ONE:
Select a Mounting Location
M29598
STEP TWO:
Connect the Duct Nozzle
6
1
2
3
4
1
2
3
M29599
Choose a location that has access to a cold
water supply pipe.
Select a vertical or horizontal surface on the HVAC
supply duct, with adequate clearances, where
TrueSTEAM can be mounted.
Make sure there is a 120 VAC electrical outlet
rated for the TrueSTEAM model being installed.
TrueSTEAM
Required Minimum
Model:
Circuit Capacity:
HM506
7 Amps
HM509
10 Amps
HM512
12 Amps
Ensure the location is near a drain with a high-
temperature water rating. Consult local plumbing
codes for proper drainage. If no main floor drain
is available, see "Appendix E: Advanced Draining"
on page 41.
Slide the foam gasket over the nozzle.
Make sure the o-ring gasket is properly seated
in the groove.
Insert the duct nozzle into TrueSTEAM. Twist
clockwise to ensure a tight seal.