STEP THREE:
Clean the Tank
1
STEP FOUR:
Replace the Water Level Sensor (if necessary)
WARNING: Electrocution Hazard.
TrueSTEAM must be unplugged before removing the cover. Hazardous voltage could cause
death or serious injury.
2
5
M29632
TrueSTEAM Humidification System 69-2285EF—01
Use tap water to flush loose minerals from the tank:
Sediment screen at tank's bottom is removable.
For a more thorough cleaning, soak tank in water
with CLR
rinse clean.
Tank is dishwasher safe.
Do not use hydrocarbon-based cleaners.
Unplug the power cord and carefully rub minerals
off of the heating element and tank walls. Clear the
sensor compartment holes of debris, if present.
2
M29631
Remove TrueSTEAM cover and inspect water
level sensor. If debris buildup is present, replace
1
the sensor (see below).
Remove T-30 Torx screw and lift clamp.
Remove the sensor.
3
Ensure sensor gaskets are seated properly and are in
good condition (no cracks).
4
Install a new sensor if excessive mineral deposits are
present, or if gaskets are in poor condition. See "Parts
List" on page 35.
, LimeAway
or white vinegar. Then
®
®
27