Before Wiring Truesteam; Using The Dip Switches; Step One: Remove The Truesteam Cover; Step Two: Understand The Dip Switches - Honeywell TrueSTEAM Guide D'installation

Masquer les pouces Voir aussi pour TrueSTEAM:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Before Wiring TrueSTEAM

Before wiring the TrueSTEAM:
I will read the section "Using the DIP Switches" beginning on this page
I will read the section "Deciding on the Wiring Configuration" beginning on page 14
TrueSTEAM wiring is different from evaporative pad humidifier wiring. In addition to solenoid water valve
actuation, TrueSTEAM can monitor system power and regulate system fan operation.

Using the DIP Switches

The wiring features are configured by DIP settings, which are described under the TrueSTEAM cover.
STEP ONE:
Remove the TrueSTEAM Cover
CAUTION: Voltage Hazard.
Be sure TrueSTEAM is not plugged in when removing the cover.
M29608
STEP TWO:
Understand the DIP Switches
1
On
Off
12
1
2
1
2
3
4
5
6
On
3
Off
2
3
4
5
6
Loosen the cover screw.
Slide cover out from front.
With the cover removed, you will see six DIP switches
to the left of the user interface panel. This manual
refers to DIPs 1–6 from left to right.
DIPS 1 and 2 are used for maintenance.
DIP 1 and DIP 2: Together, these two DIPs specify
how often the automatic flush cycle is performed. See
"Set the Automatic Flush Cycle Timing" on page 13.
M29609
TrueSTEAM Humidification System 69-2285EF—01

Publicité

Chapitres

Table des Matières
loading

Table des Matières