Honeywell TrueSTEAM Guide D'installation page 17

Masquer les pouces Voir aussi pour TrueSTEAM:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Note: This image is not a complete wiring diagram. It only depicts power monitoring.
See "Wiring the TrueSTEAM" on page 19.
1
TrueSTEAM
HUM
HUM
1
2
3
4
5
6
On
Off
Note: This image is not a complete wiring diagram. It only depicts power monitoring.
See "Wiring the TrueSTEAM" on page 19.
Humidity Control
HUM
HUM
Off
TrueSTEAM Humidification System 69-2285EF—01
Thermostat with
Humidity Control
HVAC System
2 3
R
C
TrueSTEAM
HVAC System
R
C
1
2
3
4
5
6
On
WIRING BASICS: CONFIGURATION 1
When using a thermostat with integrated
humidity control (such as VisionPRO IAQ
or Prestige):
The thermostat is powered by the
system transformer. In this configuration,
the thermostat must have power or
TrueSTEAM will not be able to
produce steam.
Because the thermostat knows when the
system transformer has power, set DIP 4
to UP, so that it is not looking for an R input
from the system R.
M29615
WIRING BASICS: CONFIGURATION 2
When using a humidistat separate from the
thermostat (such as H8908 or TrueIAQ):
TrueSTEAM generally supplies power
to the humidistat. In this configuration,
TrueSTEAM must monitor HVAC system
power to determine if humidity is allowed.
Leave DIP 4 in the DOWN position (factory
setting), and wire the HVAC system R and
C to the TrueSTEAM R and C. TrueSTEAM
will verify power is present before allowing
steam production.
M29616