Connecting the electrical power to the generator
10.3
Connecting 230 V
A
NOTICE!
• Connect a relay or a switch to the vehicle's electrical system so that
the generator is not damaged when the external mains is connected.
• Ensure that the electrical system is set up as follows:
– TN network:
The neutral conductor must be linked to the PE conductor on the
terminal via a jumper with a minimum diameter of 2.5 mm
protect against automatic shutdown, make sure that a safety
switch (FI switch, 30 mA) and an in all-pole overcurrent protec-
tion (e.g. circuit breaker, 13 A) are installed.
– IT network:
Ensure that an insulation monitor and an in all-pole overcurrent
protection (e.g. circuit breaker, 13 A) are installed.
• Connect the generator so that it takes priority over the power supply.
➤ Guide the 230 V connection cable through the cable passage in the housing and
connect it to the 230 V terminals (for TEC29 EV: fig. e 7, page 10, for
TEC29 EVLPG: fig. f 6, page 10).
➤ Connect the earth cable to the earth connection on (for TEC29 EV: fig. e 6,
page 10, for TEC29 EVLPG: fig. f 7, page 10).
10.4
Connecting the battery charger
➤ Connect the positive terminal of the battery with the 12 V connection of the bat-
tery charger using a cable with a cross-section of 2.5 mm² (for TEC29 EV:
fig. e 5, page 10, for TEC29 EVLPG: fig. f 8, page 10).
➤ If the battery to be charged is not also the starter battery, connect the negative
terminal of the battery to be charged to the generator's earth cable (fig. g 1,
page 11).
28
TEC29 EV, TEC29 EV LPG