fåëí~ää~íáçå=çå=éêÉÑ~ÄêáÅ~íÉÇ=ÄÉÇéä~íÉ=
Fig. 4: Installation of concrete column (prefabricated
bedplate)
Wechsel ein-auf zweispaltig
4
The operator / owner is responsible for the secure installation
of the charging system according to the following
specification.
For mounting, MENNEKES recommends threaded bolts
and nuts both made of stainless steel with a strength
class of at least 70 (tensile strength 700 N/mm²). Use
only threaded bolts and nuts made of stainless steel to
prevent corrosion.
When using a prefabricated bedplate, M16 threaded sleeves
for mounting are included.
The necessary mounting hardware is not included.
A
Place the prefabricated bedplate in the ground. Route
connecting cables through the empty conduit in the
prefabricated bedplate. Cable length from top edge of
bedplate approx. 2.5 m!
B
Route connecting cable
conduits in the concrete column as illustrated.
B
Place concrete column on bedplate. Secure the concrete
column with two M16 x 80 screws
torque spanner (tightening torque depending on selected
screws).
3
through one of the empty
2
and tighten with a