4
Exposed installation
1.
Insert the frost-proof outer fitting (3) into the hole and attach using the
two M6 screws (4) provided.
2.
Connect the outer fitting (3) to the water supply
(copper pipe Ø 15 mm or AG R ½")
3.
Insert the spray protection plate (9) with the central hole (Ø 35 mm)
below the frost-proof outer fitting, and connect to the attachment points
provided on the rear wall using the M6 screws provided (10).
Note!
The valve seat (thread R ½") must be located in the frost-free area.
Note!
The specifications given under Point 1 Minimum wall thicknesses
must be observed!
Installation of frost-proof outer
fitting and spray protection
Concealed installation
Installation of the trim frame with
5
door to the built-in wall cabinet
1.
Push the trim frame with door (8) with the lateral guide slots over the
(pre-assembled) screws, until the frame lies flush with the outer wall of
the building.
2.
Then secure the trim frame with door (8) using the screws.
The integral flap for hose and cable connection is for safety purposes during use.