Kemper MINI-TRESOR Instructions D'installation Et D'utilisation page 12

Armoire murale encastrée en acier inoxydable

Publicité

Les langues disponibles
  • FR

Les langues disponibles

EN
2
Info!
Following figures are delivered with protection type IP 55:
21002015CH I 21003015CH I 21004015CH
21412015CH I 21413015CH I 21414015CH
When fitting the built-in wall cabinet (1), take into account the later wall
construction of the outer façade. Max. possible compensation by the trim
frame: 20 mm!
1.
remove the pre-stamped plate for the outer fitting
2.
drill horizontally from outside to inside
Insulation without fire protection jacket.
Insulaiton on the back side is recommended (e.g. expanded polystyrene).
1.
Insert rear insulation.
2.
Insert the cabinet into the opening and fix it.
3.
If necessary, drill four holes and attach the cabinet (1) to the rear wall
using the four attachment screws provided (2) (four holes, Ø 8 mm).
Installation of built-in wall cabinet
Provide the power supply
- Note FI fuse:
Nominal fault current ≤ 0.03 A
and Connection current ≤ 32 A
- Protection type IP 44
Metallic parts of the building, to which the wall cabinet belongs, have
to be earthed.
The cross section of the wire is half the cross section of the main earth wire
of the building, or at least 6 mm².
If fire protection lagging is necessary
1.
Insert fire protection lagging into the masonry recess.
2.
Insert the cabinet (1).
* A hole of ≥ Ø 27 mm is required for the frost-proof outer fitting (3). The
pre-stamped hole in the built-in wall cabinet (1) can be used as a template.
A slope of max. 2 % must be maintained from inside to outside.
© www.kemper-olpe.de – 11.2021 / K410021000001-00 – 12 /36
Danger! Earthing!
Connect the earthing with the
intended screws at the upper
part of the wall cabinet and
the door (All metallic parts are
earthed by this).