8. Dismounting, return and disposal

8. Dismounting, return and disposal
Personnel: Skilled personnel
Tools: Screwdriver, diagonal pliers
EN
8.1 Dismounting
WARNING!
Physical injuries and damage to property and the environment
through residual media
Upon contact with hazardous media (e.g. oxygen, acetylene, flammable
or toxic substances), harmful media (e.g. corrosive, toxic, carcinogenic,
radioactive), and also with refrigeration plants and compressors, there is a
danger of physical injuries and damage to property and the environment.
WARNING!
Risk of burns
During dismounting there is a risk of dangerously hot media escaping.
DANGER!
Danger to life caused by electric current
Upon contact with live parts, there is a direct danger to life.
WARNING!
Physical injury
When dismounting, there is a danger from aggressive media and high
pressures.
14
Before storage of the dismounted instrument (following use) wash or
clean it, in order to protect persons and the environment from exposure
to residual media.
Observe the information in the material safety data sheet for the
corresponding medium.
Wash or clean the dismounted instrument, in order to protect persons
and the environment from exposure to residual media.
Let the instrument cool down sufficiently before dismounting it!
The dismounting of the instrument may only be carried out by skilled
personnel.
Only demount the strap-on thermometer in a de-energized state.
Observe the information in the material safety data sheet for the
corresponding medium.
Only dismount the strap-on thermometer in an unpowered state.