Inputs; Input E1 - External Release; Input E2 - External Door Contact; Input E3 - Central Locking - Assa Abloy Hi-O Technology One Systems N5950 Notice D'installation Et De Montage

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

I
A
EN
40

Inputs

Input
E1
– External release
A release button (or other potential-free tripping contact) can be connected to the output ("DIP switch",
page 46). The tripping contact activates different processes depending on the Hi-O Technology™ de-
vices connected:
· a motorised lock retracts the deadbolt(s),
· a coupling lock engages the outer door handle,
· An electricstrike is unlocked.
Note!
Central locking or fire alarm prevent an external release: If the door was locked centrally or a fire alarm
is activated, the door cannot be unlocked via the external release input. The external release only takes ef-
fect once the central locking and fire alarm have been withdrawn.
Input
E2
– External door contact
At tention!
Relay
R7
can only be switched when the input is closed: An additional potential-free door contact (such
as a reed contact), which queries the door position, can be connected to the input.
Relay
R7
door closed can only be switched when the external door contact input is closed.
· Close the input with a jumper if an external door contact is not connected.
If an additional external door contact is connected, the lock's internal door contact will remain active. This
means that: with these locks, both door contacts must be closed so that the door status closed is recog-
nised and relay
R7
is switched to door closed.
A wire jumper is pre-installed at input
Input
E3
– Central locking
The tripping contact of a central locking system can be connected to the input.
The tripping contact activates different processes depending on the Hi-O Technology™ devices con-
nected:
· an unlocked motorised lock is locked as soon as the door is closed,
· a coupling lock disengages the outer door handle,
· an electricstrike is locked.
In the case of central locking, local unlocking will be blocked by the external release input until the central
locking has been withdrawn („Input
E2
by default as delivered.
E1
– External release").
Inputs and outputs

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Hi-o technology onesystem io-modul n5950

Table des Matières