3.6

ELECTRICAL WIRING

Do not swap over neutral and phase; carefully follow the diagram shown and carry out a
good earth connection.
The cross section of the conductors must be at least 1 mm
standards and legislation).
ATTENTION
The electrical wiring carried out by the installer must comply with the rules in force in the country.
TESTING
Check the burner has stopped by opening the thermostats.
Check the burner has locked out during operation by opening the connector (CN1) inserted in the probe's red wire,
located outside the control box.
SO
CN1
N +
RPM
S2
L2
P P
N
S1
R
RS
PS
PE
TB
B4 S3 T2 T1 N
X7
TL
SB
h1
D8426
230 V
220/
3425
CARRIED OUT
IN THE FACTORY
G
PG
N
N
A
C
M
B
L1
BY INSTALLER
TS
KEY TO LAYOUT
BN
BK
BU
T6A
RD
WH
CN1 – Probe connector
I
M
RS
P
PG
N PE L
50/60Hz
2
. (Unless requested otherwise by local
V
I
XM1
N
L
XM3
TO BE DONE
– Brown
– Black
– Blue
– Red
– White
– Igniter
– Fan motor
– Input for remote reset
button
– Bridge block
– Bridge block
6
GB
XM2
XM4
M
TB
SB
– Lockout indicator
SO
– Ionisation probe
TB
– Burner earth
TL
– Limit thermostat
TS
– Safety thermostat
T6A – Fuse
V
– Gas valve
X7
– 7-pin plug
XM.. – Motor plug
h1
– Counter
(230V - 0.1A max)