1.

BURNER DESCRIPTION

Gas burner with one-stage operation.
EC marking according to Gas Directive 90/396/EEC.
The burner conforms with Directives: CEM 89/336/EEC - 2004/108/CE, Low Voltage 73/23/EEC - 2006/
95/CE.
Gas train conforms with Gas Directive 90/396/EEC.
The burner has been tested to conform with the Directives EN60335 / EN50165.
To comply with the above-mentioned requirements it is necessary for the burner to be protected by a hood or
by the heat generator door. Removal of this protection must only be possible with the aid of a tool.
2
1
11
4
1 – Reset button with lockout warning
2 – Control box
3 – Gas valve
4 – Air/gas mixer in intake circuit
5 – Flange
6 – Motor
1.1

BURNER EQUIPMENT

Instruction . . . . . . . . . . . . . . . . . . . . No. 1
7-pin plug . . . . . . . . . . . . . . . . . . . . No. 1
1.2

ACCESSORIES

SOFTWARE DIAGNOSTIC KIT
A special kit is available that, by an optical link to a PC, shows the burner life together with operating hours, type
and number of lockouts, serial number and no. of motor rpm's.
To display the diagnostic, proceed as follows:
Connect the kit supplied separately to the appropriate socket on the control box.
The information is read after the software program in the kit is booted.
3425
12
8
6
Fig. 1
7
9
10
7 – Combustion head with metal mesh
8 – Motor control box
9 – Igniter
10 – Flame detection probe
11 – 7-pin plug
12 – Flame inspection window
Spare parts list. . . . . . . . . . . . . . . . . . . . . . . . . . No. 1